
Wholesale Macurco GD-6 Gas Detector Supplier Form Uzbekistan
лв 481.90 - лв 491.90 (UZS)
Minimum order quantity |
![]() |
Port of dispatch | ![]() |
Processing time |
![]() |
Estimate pricing | ![]() |
Packaging | ![]() |
Availability | ![]() |
Products Description
Alarm relay is activated if gas reaches or exceeds the alarm settings
Low level meter capable of displaying from 0-50% LEL EX Display, Control & Calibration
Selectable (on/off) digital display, buzzer, fan delay minutes), fan minimum run time
Selectable fan and alarm relay activation
ETL Listed to UL 61010-1
Supervised system design: internal detector malfunction will cause the fan & alarm relay to activate
One screw allows access for calibration
Factory calibrated. Can also be field calibrated using 10% LEL Methane, 10% LEL Propane, or 10% LEL Hydrogen gas, regulator and calibration hood
The Macurco GD-6 is an all-in-one detector, controller, and transducer that lets you select between Methane (NG), Propane (LP) or Hydrogen Gas (H2) detection.
Ultra-sensitive, low-level detection at its finest, the GD-6 features advanced combustible gas monitoring in an easy-to-maintain unit that's factory calibrated for quick installation. The automatic feedback and fan control helps reduce combustible gas in a variety of environments, including parking garages, battery rooms, and maintenance facilities.
The GD-6 is also available in White.
A GD-6 is usually located in areas where there is potential for gas leaks; where there are gas appliances, areas through which gas pipes pass, where batteries are being stored or charged, etc. DO NOT mount the GD-6 in a corner. DO NOT mount the GD-6 where the normal ambient temperature is below 0F or exceeds 125F (-18C to 52C). If the target gas is lighter than air; natural gas (Methane) or Hydrogen (H2), mount the GD-6 high on a wall or column about one foot down from the ceiling. If the target gas is heavier than air; propane (LP), mount the GD-6 low on a wall or column one foot above the floor. Use the same spacing as for smoke detectors, 30 foot centers, 900 square feet per detector.
UPC: 051131498860
Also known as: MA-GD6, GD6
Technical Specifications:
Operating environ: 0°F to 125°F (-18°C to 52°C).10 to 90% RH
Current loop, 4-20 mA for 0-50% LEL
Alarm relay settings: OFF, 5, 10, 15, 20 (default), 25% LEL
Alarm relay actuation: selectable N.O. default or N.C.
Alarm relay: 0.5A 200 V, 10 VA
Fan Minimum Run Time settings are OFF (default), 3, 5, 10 or 15 minutes
Fan Delay Settings of 0, 1, 3 (default), 5 and 10 minutes