Wholesale Macurco GD-6 Gas Detector Supplier Form Uzbekistan

лв 481.90 - лв 491.90 (UZS)

Minimum order quantity 5 Piece
Port of dispatch Contact Supplier
Processing time Contact Supplier
Estimate pricing Contact Supplier
Packaging Contact Supplier
Availability In stock

Products Description

Alarm relay is activated if gas reaches or exceeds the alarm settings Low level meter capable of displaying from 0-50% LEL EX Display, Control & Calibration Selectable (on/off) digital display, buzzer, fan delay minutes), fan minimum run time Selectable fan and alarm relay activation ETL Listed to UL 61010-1 Supervised system design: internal detector malfunction will cause the fan & alarm relay to activate One screw allows access for calibration Factory calibrated. Can also be field calibrated using 10% LEL Methane, 10% LEL Propane, or 10% LEL Hydrogen gas, regulator and calibration hood The Macurco GD-6 is an all-in-one detector, controller, and transducer that lets you select between Methane (NG), Propane (LP) or Hydrogen Gas (H2) detection. Ultra-sensitive, low-level detection at its finest, the GD-6 features advanced combustible gas monitoring in an easy-to-maintain unit that's factory calibrated for quick installation. The automatic feedback and fan control helps reduce combustible gas in a variety of environments, including parking garages, battery rooms, and maintenance facilities. The GD-6 is also available in White. A GD-6 is usually located in areas where there is potential for gas leaks; where there are gas appliances, areas through which gas pipes pass, where batteries are being stored or charged, etc. DO NOT mount the GD-6 in a corner. DO NOT mount the GD-6 where the normal ambient temperature is below 0F or exceeds 125F (-18C to 52C). If the target gas is lighter than air; natural gas (Methane) or Hydrogen (H2), mount the GD-6 high on a wall or column about one foot down from the ceiling. If the target gas is heavier than air; propane (LP), mount the GD-6 low on a wall or column one foot above the floor. Use the same spacing as for smoke detectors, 30 foot centers, 900 square feet per detector. UPC: 051131498860 Also known as: MA-GD6, GD6 Technical Specifications: Operating environ: 0°F to 125°F (-18°C to 52°C).10 to 90% RH Current loop, 4-20 mA for 0-50% LEL Alarm relay settings: OFF, 5, 10, 15, 20 (default), 25% LEL Alarm relay actuation: selectable N.O. default or N.C. Alarm relay: 0.5A 200 V, 10 VA Fan Minimum Run Time settings are OFF (default), 3, 5, 10 or 15 minutes Fan Delay Settings of 0, 1, 3 (default), 5 and 10 minutes

Similar Products

T H E P U L S E O F G L O B A L T R A D E